RepairNorth Bellmore, NY·Central AC
No-Cool AC Repair: Failed Capacitor Replaced in North Bellmore
See the job
Repair · Plainview, NY · May 2026
A split AC that stopped blowing cold gets a nitrogen leak test, a full outdoor-unit cleanout and an R-410A recharge.
Before
AfterPhotos are lightly enhanced for clarity. The work shown is as installed or serviced.
The homeowner reached out because the central air had stopped blowing cold. An AC that won't cool can have more than one thing going on, so both the refrigerant side and the airflow side needed a look. On the second visit, with the condenser top off, part of the picture came into view. Dead leaves were packed deep around the compressor, the condenser coil face was matted with lint and dirt, and the return air filters were heavily loaded with dust. A coil smothered in debris struggles to shed the heat it pulls out of the house, and clogged filters cut airflow across the indoor coil, so both work against cooling.
The first visit was about diagnosis. Our technician connected gauges and ran a standing pressure test with dry nitrogen to check the refrigerant circuit for leaks, then opened up the attic air handler to inspect the evaporator coil and the expansion valve area. On the second visit, the outdoor unit's top and fan assembly came off so the leaves and debris could be cleared out of the cabinet. As part of a premium AC tune-up, the coil was cleaned with foaming coil cleaners and worked over with a fin comb. The system was evacuated with a vacuum pump and recharged with R-410A, and UV leak-detection dye was also added to the system. The dye travels with the refrigerant and glows under a UV light wherever it escapes. A new MERV 11 filter went in, condensate pan tablets were added to keep algae down, and the suction line insulation at the air handler was closed back up and sealed with foil wrap.
By the end of the second visit, the refrigerant circuit had been pressure-tested, evacuated and recharged, the outdoor coil and cabinet had been cleaned out, and a fresh MERV 11 filter was installed. The suction line insulation in the attic was sealed back up, which helps keep that cold line from sweating. The UV dye added during service also gives a quick way to trace the source if the charge ever drops again.
Book a visit online or call the office. We will look at your system and tell you what it needs.